BITE Test of the ILS 2 Inoperative
TASK 34-36-00-810-825-A
BITE Test of the ILS 2 Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-074-A
Subtask 34-36-00-810-078-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:59 UTC
BITE Test of the ILS 2 Inoperative
1. Possible Causes
- MMR-2 [40RT2]
- LGCIU-2 [5GA2]
wiring of the GROUND/AIR discrete from the MMR-2 (40RT2) to the LGCIU (5GA2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343601 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-074-A
A. Test
(1) Not applicable, the fault is evident.
4. Fault Isolation(1) Not applicable, the fault is evident.
Subtask 34-36-00-810-078-B
A. If you cannot start the BITE test of the MMR 2 on the MCDU:
Subtask 34-36-00-740-075-B - replace the MMR-2 [40RT2] , AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring of the GROUND/AIR discrete from the MMR-2 (40RT2) to the LGCIU (5GA2) ASM 343601.