Loss of the Altitude Data on the ISIS Indicator
TASK 34-22-00-810-805-A
Loss of the Altitude Data on the ISIS Indicator
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-22-00-700-051-A ** ON A/C NOT FOR ALL
Subtask 34-22-00-810-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:55 UTC
Loss of the Altitude Data on the ISIS Indicator
1. Possible Causes
- IND-ISIS [22FN]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-16-000-001 | Removal of the Static Probe |
| AMM 34-11-16-400-002 | Installation of the Static Probe |
| AMM 34-22-25-000-001 | Removal of the ISIS Indicator |
| AMM 34-22-25-170-001 | Draining and Flushing of the Standby Static and Standby Total Pressure lines (ISIS) |
| AMM 34-22-25-400-001 | Installation of the ISIS Indicator |
Subtask 34-22-00-700-051-A ** ON A/C NOT FOR ALL
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-22-00-810-055-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message on the face of the ISIS indicator:
ISIS(22FN-10FC) ALTITUDE FUNCTION
and by the red flag on the face of the ISIS indicator:
ALT
ISIS(22FN-10FC) ALTITUDE FUNCTION
and by the red flag on the face of the ISIS indicator:
ALT
- do a visual check of the standby static probes.
- replace the defective standby static probe AMM 34-11-16-000-001 AMM 34-11-16-400-002.
- drain and flush the standby static pressure line AMM 34-22-25-170-001.
- replace the IND-ISIS [22FN] AMM 34-22-25-000-001 AMM 34-22-25-400-001.