Standby Altitude Information no Accurate
TASK 34-21-00-810-803-A
Standby Altitude Information no Accurate
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-21-00-720-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-21-00-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:55 UTC
Standby Altitude Information no Accurate
1. Possible Causes
- ALTM-STANDBY [3FN]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-10-00-170-003 | Draining and Flushing of Standby Pneumatic Circuits |
| AMM 34-21-00-720-002 | Functional Test of the Standby Altimeter |
| AMM 34-21-22-000-001 | Removal of the Standby Altimeter |
| AMM 34-21-22-400-001 | Installation of the Standby Altimeter |
Subtask 34-21-00-720-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-21-00-810-052-A ** ON A/C NOT FOR ALL
A. If the standby altimeter shows out of tolerance values:
Subtask 34-21-00-720-053-A ** ON A/C NOT FOR ALL - replace the ALTM-STANDBY [3FN] AMM 34-21-22-000-001 and AMM 34-21-22-400-001.
- drain and flush the standby static pressure line AMM 34-10-00-170-003.
B. Do the test given in Para. 3.