NAV IR X FAULT or NAV ADR X FAULT ECAM Warning without Maintenance Message
TASK 34-14-00-810-996-A
NAV IR X FAULT or NAV ADR X FAULT ECAM Warning without Maintenance Message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-875-050-A ** ON A/C NOT FOR ALL
Subtask 34-14-00-810-256-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:55 UTC
NAV IR X FAULT or NAV ADR X FAULT ECAM Warning without Maintenance Message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-003 | SYSTEM TEST of the ADR |
| AMM 34-14-00-740-004 | SYSTEM TEST of the Inertial Reference (IR) |
Subtask 34-14-00-875-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 34-14-00-700-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 40RT1 (MMR1) | |||
| 49VU | NAV/MMR/1 | 42RT1 | G12 |
| FOR FIN: 40RT2 (MMR2) | |||
| 121VU | COM NAV/MMR/2 | 42RT2 | L07 |
| FOR FIN: 1FP1 (ADIRU1) | |||
| 49VU | NAV PROBES/ADIRU 1/AND AOA 1/26VAC | 5FP1 | F07 |
| FOR FIN: 1FP2 (ADIRU2) | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
| FOR FIN: 1FP3 (ADIRU3) | |||
| 121VU | ADIRS/ADIRU/3/26VAC AND AOA | 5FP3 | N07 |
B. Open, safety and tag these circuit breakers: 42RT1, 42RT2, 5FP1, 5FP2 and 5FP3.
4. Fault Isolation- Do the system test of the IR related to the ECAM warning AMM 34-14-00-740-004.
Subtask 34-14-00-810-256-A ** ON A/C NOT FOR ALL
A. Do a check to see if the test gives one of the maintenance messages that follow:
Subtask 34-14-00-720-050-A ** ON A/C NOT FOR ALL - MMR1-GPSSU1(40RT1-1SN1) ADIRU1(1FP1)
- MMR1-GPSSU1(40RT1-1SN1) ADIRU2(1FP2)
- MMR1-GPSSU1(40RT1-1SN1) ADIRU3(1FP3)
- MMR2-GPSSU2(40RT2-1SN2) ADIRU1(1FP1)
- MMR2-GPSSU2(40RT2-1SN2) ADIRU2(1FP2)
- MMR2-GPSSU2(40RT2-1SN2) ADIRU3(1FP3).
- Do the system test of the ADR related to the ECAM warning AMM 34-13-00-740-003.
- AOA SENSOR1 (3FP1) SUPPLY/ ADIRU1 (1FP1)
- AOA SENSOR2 (3FP2) SUPPLY/ ADIRU2 (1FP2)
- AOA SENSOR3 (3FP3) SUPPLY/ ADIRU3 (1FP3).
- Remove the safety clips and the tags and close these circuit breakers: 42RT1, 42RT2, 5FP1, 5FP2 and 5FP3.
- ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.B.