Loss of the GPSSU2 Input on the ADIRU3
TASK 34-14-00-810-995-A
Loss of the GPSSU2 Input on the ADIRU3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-382-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-254-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:55 UTC
Loss of the GPSSU2 Input on the ADIRU3
1. Possible Causes
- MMR-2 [40RT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-14-00-740-001 | Interface Test of the IR |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-14-00-740-382-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-254-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message GPSSU2 (1SN2):
Subtask 34-14-00-740-383-B ** ON A/C NOT FOR ALL - read the POST FLIGHT REPORT for other GPSSU2 (1SN2) maintenance messages (ATA 34-58-31 source IR1, IR2).
NOTE: In this case the GPSSU2 message is for the GPS part of the MMR2.
(1) If there is a minimum of one maintenance message: - replace the MMR-2 [40RT2] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
B. Do the test given in Para. 3.