Failure of the ADIRS CDU
TASK 34-14-00-810-974-A
Failure of the ADIRS CDU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-343-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-230-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:53 UTC
Failure of the ADIRS CDU
1. Possible Causes
- CDU-ADIRS [2FP]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-12-000-001 | Removal of the ADIRS CDU |
| AMM 34-12-12-400-001 | Installation of the ADIRS CDU |
| AMM 34-14-00-740-001 | Interface Test of the IR |
Subtask 34-14-00-740-343-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-230-A ** ON A/C NOT FOR ALL
A. If the BITE tests give the maintenance messages
ADIRS CONTROL PANEL (2FP)/ADIRU1(1FP1),
ADIRS CONTROL PANEL (2FP)/ADIRU2(1FP2),
ADIRS CONTROL PANEL (2FP)/ADIRU3(1FP3) and if the STS - CDU FAULT message is shown on the ADIRS CDU (2FP) on the overhead panel 20VU:
Subtask 34-14-00-740-344-A ** ON A/C NOT FOR ALL ADIRS CONTROL PANEL (2FP)/ADIRU1(1FP1),
ADIRS CONTROL PANEL (2FP)/ADIRU2(1FP2),
ADIRS CONTROL PANEL (2FP)/ADIRU3(1FP3) and if the STS - CDU FAULT message is shown on the ADIRS CDU (2FP) on the overhead panel 20VU:
- replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001
B. Do the test given in Para. 3.