Loss of DC Supply of the ADIRU3 During Power Transfer on Ground


TASK 34-14-00-810-971-A
Loss of DC Supply of the ADIRU3 During Power Transfer on Ground


1. Possible Causes
  • RELAY-ADIRS 3 PWR SHEDDING [14FP]
  • wiring between the circuit breaker (6FP3) and the ADIRU3 (1FP3)
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-30-00-040-001
Do a Charging Cycle of the Battery Connected with the Battery Charge Limiter (BCL) or Replacement of the Battery
ASM 341101
3. Fault Confirmation
Subtask 34-14-00-710-087-A
A. Test
Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-14-00-810-227-A ** ON A/C NOT FOR ALL
A. If the FAULT annunciator light of the IR3 comes on, on the Control and Display Unit (CDU) during power transfer on ground:
   (1) If the battery 1 charge is correct:
  • replace the RELAY-ADIRS 3 PWR SHEDDING [14FP]
     (a) If the fault continues:
  • do a check and repair the wiring between the circuit breaker (6FP3) and the ADIRU3 (1FP3): for pin AC/7 of the ADIRU3 ASM 341101.
Subtask 34-14-00-810-227-B ** ON A/C NOT FOR ALL
A. If the FAULT legend of the IR3 pushbutton switch comes on, on the Mode Selector Unit (MSU) during power transfer on ground:
   (1) If the battery 1 charge is correct:
  • Replace the RELAY-ADIRS 3 PWR SHEDDING [14FP] .
     (a) If the fault continues:
  • Do a check and repair the wiring between the ADIRS/ADIRU/3/28VDC circuit breaker (6FP3) and pin AC/7 of the ADIRU3 (1FP3) ASM 341101.