Loss of DC Supply of the ADIRU3 During Power Transfer on Ground
TASK 34-14-00-810-971-A
Loss of DC Supply of the ADIRU3 During Power Transfer on Ground
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-710-087-A
Subtask 34-14-00-810-227-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:53 UTC
Loss of DC Supply of the ADIRU3 During Power Transfer on Ground
1. Possible Causes
- RELAY-ADIRS 3 PWR SHEDDING [14FP]
wiring between the circuit breaker (6FP3) and the ADIRU3 (1FP3) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-30-00-040-001 | Do a Charging Cycle of the Battery Connected with the Battery Charge Limiter (BCL) or Replacement of the Battery |
| ASM 341101 |
Subtask 34-14-00-710-087-A
A. Test
Not applicable, the fault is evident.
4. Fault IsolationNot applicable, the fault is evident.
Subtask 34-14-00-810-227-A ** ON A/C NOT FOR ALL
A. If the FAULT annunciator light of the IR3 comes on, on the Control and Display Unit (CDU) during power transfer on ground:
Subtask 34-14-00-810-227-B ** ON A/C NOT FOR ALL - do a charging cycle on the battery 1 AMM 24-30-00-040-001.
- replace the RELAY-ADIRS 3 PWR SHEDDING [14FP]
- do a check and repair the
wiring between the circuit breaker (6FP3) and the ADIRU3 (1FP3) : for pin AC/7 of the ADIRU3 ASM 341101.
A. If the FAULT legend of the IR3 pushbutton switch comes on, on the Mode Selector Unit (MSU) during power transfer on ground:
- Do a charging cycle on the battery 1 AMM 24-30-00-040-001.
- Replace the RELAY-ADIRS 3 PWR SHEDDING [14FP] .
- Do a check and repair the wiring between the ADIRS/ADIRU/3/28VDC circuit breaker (6FP3) and pin AC/7 of the ADIRU3 (1FP3) ASM 341101.