Loss of the IR3 Data Identified by the EFCS1
TASK 34-14-00-810-965-A
Loss of the IR3 Data Identified by the EFCS1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-335-A 4. Fault Isolation
Subtask 34-14-00-810-221-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:52 UTC
Loss of the IR3 Data Identified by the EFCS1
1. Possible Causes
- ADIRU-3 [1FP3]
- wiring between the ADIRU 3 and the first terminal block
- wiring between the ADIRU 3 and the terminal block 1831VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341401 |
Subtask 34-14-00-740-335-A 4. Fault Isolation
Subtask 34-14-00-810-221-A
A. If the test gives the maintenance message IR3:
Subtask 34-14-00-740-336-A - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- remove the ADIRU 3
- do a check of the wiring between the ADIRU 3 and the first terminal block : for pins AB/5E, 6E of the ADIRU 3 ASM 341401
- repair it
- install the ADIRU 3.
- do a check of the wiring between the ADIRU 3 and the terminal block 1831VT : for pins AB/10C, 11C of the ADIRU 3 ASM 341401
- repair the above wiring
- install the ADIRU 3.
- do the trouble shooting procedure that follows (Ref. TSM TASK 31-32-00-810-934).
B. Do the test given in Para. 3.