W DOC AIRBUS | TSM A320F

Loss of the IR1 Data Identified by the EFCS1


TASK 34-14-00-810-963-A
Loss of the IR1 Data Identified by the EFCS1


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring between the ADIRU 1 and the first terminal block
  • wiring between the ADIRU 1 and the terminal block 1831VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-934-A
Failure of the Digital Links
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341401
3. Fault Confirmation
Subtask 34-14-00-740-331-A
A. Test
   (1) Do the BITE test of the EFCS (Ground scanning) (system 1) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-219-A
A. If the test gives the maintenance message IR1:
   (1) If the fault continues:
  • remove the ADIRU 1
  • do a check of the wiring between the ADIRU 1 and the first terminal block : for pins AB/5E, 6E of the ADIRU 1 ASM 341401
     (a) If the wiring is not ok:
  • repair it
  • install the ADIRU 1.
     (b) If the wiring is ok:
  • do a check of the wiring between the ADIRU 1 and the terminal block 1831VT : for pins AB/10C, 11C of the ADIRU 1 ASM 341401
       1 If the above wiring is not ok:
  • repair it
  • install the ADIRU 1.
       2 If the above wiring is ok:
Subtask 34-14-00-740-332-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:52 UTC