W DOC AIRBUS | TSM A320F

Loss of the ADIRS CDU Data Input on the ADIRU3


TASK 34-14-00-810-931-A
Loss of the ADIRS CDU Data Input on the ADIRU3


1. Possible Causes
  • CDU-ADIRS [2FP]
  • ADIRU-3 [1FP3]
  • wiring of the CDU OUTPUT bus from the ADIRS CDU (2FP) to the ADIRU3 (1FP3)
  • wiring of the CDU DSPL SELECT discrete from the ADIRS CDU (2FP) to the ADIRU3 (1FP3)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-12-000-001
Removal of the ADIRS CDU
AMM 34-12-12-400-001
Installation of the ADIRS CDU
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
ASM 341402
3. Fault Confirmation
Subtask 34-14-00-740-267-A
A. Test
   (1) Do the Interface test of the IR (system 3) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-185-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message ADIRS CTLPNL (2FP):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check of the wiring of the CDU OUTPUT bus from the ADIRS CDU (2FP) to the ADIRU3 (1FP3) ASM 341402.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • do a check and repair the wiring of the CDU DSPL SELECT discrete from the ADIRS CDU (2FP) to the ADIRU3 (1FP3) ASM 341402.
Subtask 34-14-00-740-268-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:50 UTC