Loss of the ADIRS CDU Data Input on the ADIRU2
TASK 34-14-00-810-930-A
Loss of the ADIRS CDU Data Input on the ADIRU2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-265-A 4. Fault Isolation
Subtask 34-14-00-810-184-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:50 UTC
Loss of the ADIRS CDU Data Input on the ADIRU2
1. Possible Causes
- CDU-ADIRS [2FP]
- ADIRU-2 [1FP2]
wiring of the CDU OUTPUT bus from the ADIRS CDU (2FP) to the ADIRU2 (1FP2) wiring of the CDU DSPL SELECT discrete from the ADIRS CDU (2FP) to the ADIRU2 (1FP2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-12-000-001 | Removal of the ADIRS CDU |
| AMM 34-12-12-400-001 | Installation of the ADIRS CDU |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-14-00-740-001 | Interface Test of the IR |
| ASM 341402 |
Subtask 34-14-00-740-265-A 4. Fault Isolation
Subtask 34-14-00-810-184-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message ADIRS CTLPNL (2FP):
Subtask 34-14-00-740-266-A - replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check of the
wiring of the CDU OUTPUT bus from the ADIRS CDU (2FP) to the ADIRU2 (1FP2) ASM 341402.
- repair the above wiring.
- do a check and repair the
wiring of the CDU DSPL SELECT discrete from the ADIRS CDU (2FP) to the ADIRU2 (1FP2) ASM 341402.
B. Do the test given in Para. 3.