W DOC AIRBUS | TSM A320F

Failure of the Cooling Air System of the IR1


TASK 34-14-00-810-920-A
Failure of the Cooling Air System of the IR1


1. Possible Causes
  • ADIRU-1 [1FP1]
  • cooling air system
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-14-00-740-251-A ** ON A/C NOT FOR ALL
A. Test
Do the Interface test of the IR (system 1) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-174-A ** ON A/C NOT FOR ALL
A. If the maintenance message ADIRU1 (1FP1)/OVER TEMPERATURE is shown:
   (1) If the system is operative:
   (2) If the system is not operative:
  • repair it and install the ADIRU 1.
Subtask 34-14-00-740-252-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.