ADIRS CDU Inoperative


TASK 34-14-00-810-892-A
ADIRS CDU Inoperative


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341101
AMM 34-12-12-000-001
Removal of the ADIRS CDU
AMM 34-12-12-400-001
Installation of the ADIRS CDU
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-14-00-740-195-A
A. Test
   (1) Do the Interface test of the IR AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-144-C ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message ADIRS CTLPNL (2FP/221VU)/ ADIRU1 (1FP1):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the CDU PWR discretes from the ADIRU1 (1FP1) to the ADIRS CDU (2FP) ASM 341101.
Subtask 34-14-00-810-145-C ** ON A/C NOT FOR ALL
B. If the BITE test gives the maintenance message ADIRS CTLPNL (2FP/221VU)/ ADIRU2 (1FP2):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the CDU PWR discretes from the ADIRU2 (1FP2) to the ADIRS CDU (2FP) ASM 341101.
Subtask 34-14-00-810-146-C ** ON A/C NOT FOR ALL
C. If the BITE test gives the maintenance message ADIRS CTLPNL (2FP/221VU)/ ADIRU3 (1FP3):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the CDU PWR discretes from the ADIRU3 (1FP3) to the ADIRS CDU (2FP) ASM 341101.
Subtask 34-14-00-740-196-A
D. Do the test given in Para. 3.