The ALIGN Legend of the IR 2 Annunciator does not come on
TASK 34-14-00-810-888-A
The ALIGN Legend of the IR 2 Annunciator does not come on
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-860-058-A ** ON A/C NOT FOR ALL Subtask 34-14-00-710-076-A ** ON A/C NOT FOR ALL
Subtask 34-14-00-810-140-A ** ON A/C NOT FOR ALL
Subtask 34-14-00-860-059-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:48 UTC
The ALIGN Legend of the IR 2 Annunciator does not come on
1. Possible Causes
- ADIRU-2 [1FP2]
- BOARD-ANN LT TEST & INTFC [18LP]
wiring of the ALIGN discrete from the ADIRU2 (1FP2) to the annunciator light test and interface board (18LP) - CDU-ADIRS [2FP]
wiring of the annunciator light test and interface board (18LP)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 34-10-00-860-005 | ADIRS Stop Procedure |
| AMM 34-12-12-000-001 | Removal of the ADIRS CDU |
| AMM 34-12-12-400-001 | Installation of the ADIRS CDU |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341402 |
Subtask 34-14-00-860-058-A ** ON A/C NOT FOR ALL Subtask 34-14-00-710-076-A ** ON A/C NOT FOR ALL
B. Test
(1) On the ADIRS CDU, make sure that the ALIGN legend of the IR 2 annunciator comes on.
4. Fault Isolation(1) On the ADIRS CDU, make sure that the ALIGN legend of the IR 2 annunciator comes on.
Subtask 34-14-00-810-140-A ** ON A/C NOT FOR ALL
A. If the ALIGN legend of the IR 2 annunciator does not come on:
Subtask 34-14-00-710-077-A ** ON A/C NOT FOR ALL - on the panel 25VU, set the INT LT/ANN LT switch to TEST and make sure that the ALIGN legend comes on.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the BOARD-ANN LT TEST & INTFC [18LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- do a check and repair the
wiring of the ALIGN discrete from the ADIRU2 (1FP2) to the annunciator light test and interface board (18LP) ASM 341402.
- replace the BOARD-ANN LT TEST & INTFC [18LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001.
- do a check and repair the
wiring of the annunciator light test and interface board (18LP)
. from pin A/22 to ADIRS CDU (2FP) pin B/14
. from pin A/23 to the ground point ASM 341402.
B. Do the test given in Para. 3.B.
5. Close-upSubtask 34-14-00-860-059-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the panel 25VU, set the ANN LT switch to BRT.
(2) Do the ADIRS stop procedure AMM 34-10-00-860-005.
(1) On the panel 25VU, set the ANN LT switch to BRT.
(2) Do the ADIRS stop procedure AMM 34-10-00-860-005.