The FAULT Legend of the IR 3 Annunciator does not come on while the related Warning is shown on the Upper ECAM DU
TASK 34-14-00-810-886-A
The FAULT Legend of the IR 3 Annunciator does not come on while the related Warning is shown on the Upper ECAM DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-860-054-A Subtask 34-14-00-865-061-A
Subtask 34-14-00-810-138-A ** ON A/C NOT FOR ALL
Subtask 34-14-00-860-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:48 UTC
The FAULT Legend of the IR 3 Annunciator does not come on while the related Warning is shown on the Upper ECAM DU
1. Possible Causes
- ADIRU-3 [1FP3]
- BOARD-ANN LT TEST & INTFC [4LP]
wiring of the IR FAULT WARN discrete from the ADIRU3 (1FP3) to the annunciator light test and interface board (4LP) - CDU-ADIRS [2FP]
wiring of the annunciator light test and interface board (4LP) P/BSW-ADIRS/IR3 (24FP3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 34-10-00-860-005 | ADIRS Stop Procedure |
| AMM 34-12-12-000-001 | Removal of the ADIRS CDU |
| AMM 34-12-12-400-001 | Installation of the ADIRS CDU |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341402 |
Subtask 34-14-00-860-054-A Subtask 34-14-00-865-061-A
B. Table of the circuit breakers used in this procedure:
Subtask 34-14-00-710-072-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 121VU | ADIRS/ADIRU/3/28VDC | 6FP3 | N03 |
C. Test
Subtask 34-14-00-710-072-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.Open the circuit breakers (4FP3) and (6FP3) |
|
C. Test
4. Fault Isolation| ACTION | RESULT |
|---|---|
| 1.Open the circuit breakers (4FP3) and (6FP3) |
|
Subtask 34-14-00-810-138-A ** ON A/C NOT FOR ALL
A. If the FAULT legend of the IR 3 annunciator does not come on:
Subtask 34-14-00-810-138-B ** ON A/C NOT FOR ALL - on the overhead control and indicating panel 25VU, set the INT LT/ANN LT switch to TEST and make sure that the FAULT legend comes on.
- replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the BOARD-ANN LT TEST & INTFC [4LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- do a check and repair the
wiring of the IR FAULT WARN discrete from the ADIRU3 (1FP3) to the annunciator light test and interface board (4LP) ASM 341402.
- replace the BOARD-ANN LT TEST & INTFC [4LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001:
- replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001.
- do a check and repair the
wiring of the annunciator light test and interface board (4LP)
. from pin A/18 to ADIRS CDU (2FP) pin C/17
. from pin A/34 to the ground point ASM 341402.
A. If the FAULT legend of the IR 3 pushbutton switch does not come on:
Subtask 34-14-00-710-073-A - On the overhead control and indicating panel 25VU, set the INT LT/ANN LT switch to TEST and make sure that the FAULT legend comes on.
- Replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- Replace the BOARD-ANN LT TEST & INTFC [4LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- Do a check and repair the
wiring of the IR FAULT WARN discrete from the ADIRU3 (1FP3) to the annunciator light test and interface board (4LP) ASM 341402.
- Replace the BOARD-ANN LT TEST & INTFC [4LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001:
- Replace the
P/BSW-ADIRS/IR3 (24FP3) .
- Do a check and repair the
wiring of the annunciator light test and interface board (4LP)
. from pin A/18 to pin A/7 of the ADIRS/IR3 pushbutton switch (24FP3)
. from pin A/34 to the ground point ASM 341402.
B. Do the test given in Para. 3.C.
5. Close-upSubtask 34-14-00-860-055-A
A. Put the aircraft back to its initial configuration.
(1) Close the circuit breakers (4FP3) and (6FP3).
(2) On the panel 25VU, set the ANN LT switch to BRT.
(3) Do the ADIRS stop procedure AMM 34-10-00-860-005.
(1) Close the circuit breakers (4FP3) and (6FP3).
(2) On the panel 25VU, set the ANN LT switch to BRT.
(3) Do the ADIRS stop procedure AMM 34-10-00-860-005.