W DOC AIRBUS | TSM A320F

Loss of the FMGC1 Data Input Bus on the ADIRU3


TASK 34-14-00-810-876-A
Loss of the FMGC1 Data Input Bus on the ADIRU3


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring of the FMGC1 INPUT bus from the ADIRU3 (1FP3) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
ASM 341402
3. Fault Confirmation
Subtask 34-14-00-740-191-A
A. Test
   (1) Do the Interface test of the IR (system 3) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-134-B
A. If the test gives the maintenance message FMGC1 (1CA1)/ADIRU3 (1FP3):
   (1) If the fault continues:
  • do a check and repair the wiring of the FMGC1 INPUT bus from the ADIRU3 (1FP3) to the first terminal block ASM 341402.
Subtask 34-14-00-740-192-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:47 UTC