W DOC AIRBUS | TSM A320F

Loss of the CFDIU Data Input Bus on the ADIRU1


TASK 34-14-00-810-869-A
Loss of the CFDIU Data Input Bus on the ADIRU1


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the CFDIU INPUT bus from the ADIRU1 (1FP1) to the first terminal bloc
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
ASM 341402
3. Fault Confirmation
Subtask 34-14-00-740-177-A
A. Test
   (1) Do the Interface test of the IR (system 1) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-127-B
A. If the BITE test gives the maintenance message CFDIU (1TW)/ADIRU1 (1FP1):
   (1) If the fault continues:
  • do a check and repair the wiring of the CFDIU INPUT bus from the ADIRU1 (1FP1) to the first terminal bloc ASM 341402.
Subtask 34-14-00-740-178-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:47 UTC