W DOC AIRBUS | TSM A320F

Loss of the IR1 Bus 3 Output Identified by the GPWC


TASK 34-14-00-810-867-A
Loss of the IR1 Bus 3 Output Identified by the GPWC


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU1 (1FP1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341401
AMM 34-48-00-740-002
BITE Test of the GPWS
3. Fault Confirmation
Subtask 34-14-00-740-173-C
A. Test
   (1) Do the BITE test of the Enhanced GPWS AMM 34-48-00-740-002.
4. Fault Isolation
Subtask 34-14-00-810-125-A
A. If the test gives the maintenance message ADIRU1 (1FP1)/GPWC (1WZ):
   (1) If the fault continues:
  • do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU1 (1FP1) to the first terminal block ASM 341401.
Subtask 34-14-00-740-174-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:47 UTC