Loss of the IR 3 BUS 3 Output Identified by the EFCS 2
TASK 34-14-00-810-860-A
Loss of the IR 3 BUS 3 Output Identified by the EFCS 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-146-A 4. Fault Isolation
Subtask 34-14-00-810-109-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:46 UTC
Loss of the IR 3 BUS 3 Output Identified by the EFCS 2
1. Possible Causes
- ADIRU-3 [1FP3]
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the terminal block 1831VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AWM 341139 | |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341401 |
Subtask 34-14-00-740-146-A 4. Fault Isolation
Subtask 34-14-00-810-109-A
A. If the test gives the maintenance message IR3 - BUS3:
Subtask 34-14-00-740-147-A - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the terminal block 1831VT : For pins AB/10C, 11C of the ADIUR3 ASM 341401 AWM 341139.
- do the trouble shooting procedure that follows (Ref. TSM TASK 31-32-00-810-934).
B. Do the test given in Para. 3.