Loss of the IR 3 BUS 3 Output Identified by the RADAR 1
TASK 34-14-00-810-857-A
Loss of the IR 3 BUS 3 Output Identified by the RADAR 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-142-A 4. Fault Isolation
Subtask 34-14-00-810-106-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:46 UTC
Loss of the IR 3 BUS 3 Output Identified by the RADAR 1
1. Possible Causes
- ADIRU-3 [1FP3]
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341401 | |
| AMM 34-41-00-740-002 | BITE Test of the Weather Radar |
Subtask 34-14-00-740-142-A 4. Fault Isolation
Subtask 34-14-00-810-106-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message RADAR 1 NO DATA FROM ADIRU:
Subtask 34-14-00-810-106-C ** ON A/C NOT FOR ALL - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block : for pins AB/10C, 11C of the ADIRU 3 ASM 341401.
A. If the test gives the maintenance message ADIRU3 (1FP3) IR BUS/WXR1 (1SQ1):
Subtask 34-14-00-740-143-A - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block : for pins AB/10C, 11C of the ADIRU 3 ASM 341401.
B. Do the test given in Para. 3.