W DOC AIRBUS | TSM A320F

Loss of the IR 3 BUS 2 Output Identified by the EFCS 2


TASK 34-14-00-810-856-A
Loss of the IR 3 BUS 2 Output Identified by the EFCS 2


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring of the INERTIAL REFERENCE OUTPUT BUS 2 bus from the ADIRU 3 (1FP3) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-934-A
Failure of the Digital Links
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341401
3. Fault Confirmation
Subtask 34-14-00-740-140-A
A. Test
Do the BITE test of the EFCS (ground scanning) (system 2) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-105-A
A. If the test gives the maintenance message IR3 - BUS2:
   (1) If the fault continues:
  • do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 2 bus from the ADIRU 3 (1FP3) to the first terminal block ASM 341401.
     (a) If the fault continues:
Subtask 34-14-00-740-141-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:46 UTC