Internal Failure of the IR 2 Identified by the EFCS 2
TASK 34-14-00-810-831-A
Internal Failure of the IR 2 Identified by the EFCS 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-100-A 4. Fault Isolation
Subtask 34-14-00-810-080-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:44 UTC
Internal Failure of the IR 2 Identified by the EFCS 2
1. Possible Causes
- ADIRU-2 [1FP2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-14-00-740-100-A 4. Fault Isolation
Subtask 34-14-00-810-080-A
A. If the test gives the maintenance message IR2:
Subtask 34-14-00-740-101-A - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.