W DOC AIRBUS | TSM A320F

Internal Failure of the IR 2 Identified by the EIS 2


TASK 34-14-00-810-827-A
Internal Failure of the IR 2 Identified by the EIS 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 34-14-00-740-094-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS input test (system 2) AMM 31-60-00-740-002.
Subtask 34-14-00-740-094-B ** ON A/C NOT FOR ALL
A. Test
Do the Ground Scanning Test of the DMC (system 2) AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 34-14-00-810-076-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : NO IRS2 DATA:
Subtask 34-14-00-810-076-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU2(1FP2)BUSX IR/DMC2(1WT2)
Subtask 34-14-00-740-095-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:44 UTC