Loss of the ADR 1 Input Data to the IR 3


TASK 34-14-00-810-819-A
Loss of the ADR 1 Input Data to the IR 3


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring of the ADR INPUT 1 signal from the ADIRU 3 (1FP3) to the first terminal block
  • wiring of the ADR INPUT 1 signal from the ADIRU3 (1FP3) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
ASM 341402
3. Fault Confirmation
Subtask 34-14-00-740-079-A
A. Test
Do the Interface test of the IR (system 3) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-068-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU3 (1FP3):
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR INPUT 1 signal from the ADIRU 3 (1FP3) to the first terminal block ASM 341402.
Subtask 34-14-00-810-068-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU1 (1FP1):
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR INPUT 1 signal from the ADIRU3 (1FP3) to the first terminal block ASM 341402.
Subtask 34-14-00-740-080-A
B. Do the test given in Para. 3.