Loss of the IR 1 BUS 3 Output Identified by the CFDS


TASK 34-14-00-810-816-A
Loss of the IR 1 BUS 3 Output Identified by the CFDS


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341401
3. Fault Confirmation
Subtask 34-14-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
Subtask 34-14-00-740-073-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 34-14-00-810-065-A
A. If the test gives the maintenance message NO IR1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block ASM 341401.
Subtask 34-14-00-740-074-A
B. Do the test given in Para. 3.