Internal Failure of the IR 1 Identified by the EIS 3
TASK 34-14-00-810-808-A
Internal Failure of the IR 1 Identified by the EIS 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-061-A ** ON A/C NOT FOR ALL Subtask 34-14-00-740-061-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:43 UTC
Internal Failure of the IR 1 Identified by the EIS 3
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-14-00-740-061-A ** ON A/C NOT FOR ALL Subtask 34-14-00-740-061-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-14-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO IRS 1 DATA:
Subtask 34-14-00-810-057-B ** ON A/C NOT FOR ALL - replace the ADIRU-1 [1FP1] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
A. If the test gives the maintenance message ADIRU1(1FP1)BUSX IR/DMC3(1WT3)
Subtask 34-14-00-740-062-A - replace the ADIRU-1 [1FP1] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.