W DOC AIRBUS | TSM A320F

Internal Failure of the IR 1


TASK 34-14-00-810-801-A
Internal Failure of the IR 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-860-001
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
AMM 34-10-00-860-004
IR Alignment Procedure
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-12-34-610-801
Uploading of Software to the ADIRUs
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-14-00-740-050-A
A. Test
Do the Interface test of the IR (system 1) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-14-00-810-050-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU1 (1FP1):
Subtask 34-14-00-810-050-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU1 (1FP1):
   (1) If the fault continues:
Subtask 34-14-00-810-231-A
B. If the test does not give the maintenance message ADIRU1 or ADIRU (1FP1) , get access to the Trouble Shooting Data.
On the center pedestal, on the one MCDU get the SYSTEM REPORT/TEST/NAV page. AMM 31-32-00-860-001
ACTION
RESULT
On the MCDU:
On the MCDU:
  • Push the line key adjacent to the IR1 indication
  • the IR1 page comes into view
  • push the line key adjacent to the TROUBLE SHOOT DATA indication
[Rev.8 from Aug 2018] 2026.04.04 04:32:41 UTC