W DOC AIRBUS | TSM A320F

Invalid Data Received from LGCIU 2 to ADR 3


TASK 34-13-81-810-892-A
Invalid Data Received from LGCIU 2 to ADR 3


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 34-13-00-740-003
SYSTEM TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-205-A ** ON A/C NOT FOR ALL
A. Test
Do the system test of the ADR 3 AMM 34-13-00-740-003.
4. Fault Isolation
Subtask 34-13-81-810-144-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message LGCIU2:
Subtask 34-13-81-740-206-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:41 UTC