W DOC AIRBUS | TSM A320F

Failure of the Input Refresh Rate or Transmission Error from LGCIU 2 to ADR 3


TASK 34-13-81-810-886-A
Failure of the Input Refresh Rate or Transmission Error from LGCIU 2 to ADR 3


1. Possible Causes
  • LGCIU-2 [5GA2]
  • aircraft wiring
  • ADIRU-3 [1FP3]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
ASM 326102
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-003
SYSTEM TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-193-A ** ON A/C NOT FOR ALL
A. Test
Do the system test of the ADR 3 AMM 34-13-00-740-003.
4. Fault Isolation
Subtask 34-13-81-810-138-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message LGCIU2/ ADIRU3(1FP3):
   (1) If the fault continues:
  • do a check for continuity of the aircraft wiring from the LGCIU 2 (5GA2) to the ADIRU 3 (1FP3):
    pins AA/13J, 15J to pins AA/14G, 14H for the BUS 2 O/P bus ASM 326102.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
Subtask 34-13-81-740-194-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:40 UTC