Failure of the Input Refresh Rate or Transmission Error from LGCIU 1 to ADR 2


TASK 34-13-81-810-882-A
Failure of the Input Refresh Rate or Transmission Error from LGCIU 1 to ADR 2


1. Possible Causes
  • LGCIU-1 [5GA1]
  • aircraft wiring
  • ADIRU-2 [1FP2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
ASM 326102
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-003
SYSTEM TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-185-A ** ON A/C NOT FOR ALL
A. Test
Do the system test of the ADR 2 AMM 34-13-00-740-003.
4. Fault Isolation
Subtask 34-13-81-810-134-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message LGCIU1/ ADIRU2(1FP2):
   (1) If the fault continues:
  • do a check for continuity of the aircraft wiring from the LGCIU 1 (5GA1) to the ADIRU 2 (1FP2):
    pins AA/13J, 15J to pins AA/7D, 7E for the BUS 2 O/P bus ASM 326102.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
Subtask 34-13-81-740-186-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.