Loss of the AOA 1 Input to the ADR 1


TASK 34-13-81-810-868-A
Loss of the AOA 1 Input to the ADR 1


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring between the ADIRU1 and the angle-of-attack sensor 1
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341102
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-157-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the interface test of the ADR (system 1) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-81-810-120-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AOA SENSOR (3FP1)/ADIRU1 (1FP1):
   (1) If the fault continues:
  • remove the ADIRU1
  • disconnect the electrical connector of the angle-of-attack sensor 1
  • do a check and repair the wiring between the ADIRU1 and the angle-of-attack sensor 1 : pins AOA INPUT 1 and 2 of the ADIRU1 ASM 341102
  • install the ADIRU1
  • connect the electrical connector of the angle-of-attack sensor 1.
Subtask 34-13-81-740-158-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:38 UTC