W DOC AIRBUS | TSM A320F

Loss of the ADR 3 BUS 3 Output


TASK 34-13-81-810-858-A
Loss of the ADR 3 BUS 3 Output


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-003
SYSTEM TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-137-A ** ON A/C NOT FOR ALL
A. Test
Do the system test of the ADR 3 AMM 34-13-00-740-003.
4. Fault Isolation
Subtask 34-13-81-810-110-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU3 (1FP3) ADR BUS 3:
Subtask 34-13-81-740-138-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:37 UTC