W DOC AIRBUS | TSM A320F

Difference between the Initial and the Current ADR 1 SDI Code


TASK 34-13-81-810-846-A
Difference between the Initial and the Current ADR 1 SDI Code


1. Possible Causes
  • ADIRU-1 [1FP1]
  • SDI pin programming of the ADIRU1
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341201
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-003
SYSTEM TEST of the ADR
AMM 34-13-00-740-005
Read the CFDIU for the ADR INPUT STATUS
3. Fault Confirmation
Subtask 34-13-81-740-113-A ** ON A/C NOT FOR ALL
A. Test
Do the system test of the ADR 1 AMM 34-13-00-740-003
4. Fault Isolation
Subtask 34-13-81-810-098-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message WRG:SDI PIN PROG:
  • read the CFDIU for the CURRENT STATUS of the ADR1 AMM 34-13-00-740-005.
  • compare the CURRENT STATUS of the ADR 1 with the status of the SDI pin programming pins AB/1A, 5A, 6A given in the ASM ASM 341201.
  • remove the ADIRU-1 [1FP1] AMM 34-12-34-000-001
  • do a check of the defective pin(s) on the rack connector.
   (1) If the pin programming is incorrect:
   (2) If the pin programming is correct:
Subtask 34-13-81-740-114-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:36 UTC