Loss of the AOA 3 Input to the ADR 3


TASK 34-13-81-810-839-A
Loss of the AOA 3 Input to the ADR 3


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring between the ADIRU3 and the angle-of-attack sensor 3
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341102
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-103-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the interface test of the ADR (system 3) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-81-810-090-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AOA SENSOR (3FP3)/ADIRU3 (1FP3):
   (1) If the fault continues:
  • remove the ADIRU3
  • disconnect the electrical connector of the angle-of-attack sensor 3
  • do a check and repair the wiring between the ADIRU3 and the angle-of-attack sensor 3 : pins AOA INPUT 1 and 2 of the ADIRU3 ASM 341102
  • install the ADIRU3
  • connect the electrical connector of the angle-of-attack sensor 3.
Subtask 34-13-81-740-104-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.