Loss of the AOA 2 Input to the ADR 2
TASK 34-13-81-810-838-A
Loss of the AOA 2 Input to the ADR 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-105-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-81-810-091-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:36 UTC
Loss of the AOA 2 Input to the ADR 2
1. Possible Causes
- ADIRU-2 [1FP2]
- wiring between the ADIRU2 and the angle-of-attack sensor 2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 341102 | |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-81-740-105-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-81-810-091-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AOA SENSOR (3FP2)/ADIRU2 (1FP2):
Subtask 34-13-81-740-106-A ** ON A/C NOT FOR ALL - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- remove the ADIRU2
- disconnect the electrical connector of the angle-of-attack sensor 2
- do a check and repair the wiring between the ADIRU2 and the angle-of-attack sensor 2 : pins AOA INPUT 1 and 2 of the ADIRU2 ASM 341102
- install the ADIRU2
- connect the electrical connector of the angle-of-attack sensor 2.
B. Do the test given in Para. 3.