Loss of the AOA 2 Input to the ADR 2


TASK 34-13-81-810-838-A
Loss of the AOA 2 Input to the ADR 2


1. Possible Causes
  • ADIRU-2 [1FP2]
  • wiring between the ADIRU2 and the angle-of-attack sensor 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341102
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-81-740-105-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-81-810-091-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AOA SENSOR (3FP2)/ADIRU2 (1FP2):
   (1) If the fault continues:
  • remove the ADIRU2
  • disconnect the electrical connector of the angle-of-attack sensor 2
  • do a check and repair the wiring between the ADIRU2 and the angle-of-attack sensor 2 : pins AOA INPUT 1 and 2 of the ADIRU2 ASM 341102
  • install the ADIRU2
  • connect the electrical connector of the angle-of-attack sensor 2.
Subtask 34-13-81-740-106-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.