Loss of the ADR 2 Data Identified by the DMC 3
TASK 34-13-81-810-833-A
Loss of the ADR 2 Data Identified by the DMC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-81-810-082-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:36 UTC
Loss of the ADR 2 Data Identified by the DMC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| ASM 341301 |
Subtask 34-13-81-740-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-81-810-082-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message
ADIRU2 (1FP2)/DMC3 (1WT3):
Subtask 34-13-81-740-095-A ** ON A/C NOT FOR ALL ADIRU2 (1FP2)/DMC3 (1WT3):
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring between the ADIRU2 (1FP2) and the DMC3 (1WT3). ASM 341301
B. Do the test given in Para. 3.