Failure of the ADR ZERO MACH-AOA Pin-Programming
TASK 34-13-81-810-827-A
Failure of the ADR ZERO MACH-AOA Pin-Programming
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-082-A 4. Fault Isolation
Subtask 34-13-81-810-076-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:35 UTC
Failure of the ADR ZERO MACH-AOA Pin-Programming
1. Possible Causes
- ADIRU-1 [1FP1]
- ADIRU-2 [1FP2]
- ADIRU-3 [1FP3]
wiring ZERO MACH-AOA pin-programming of the ADIRU-1 (2 or 3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-81-740-082-A 4. Fault Isolation
Subtask 34-13-81-810-076-A
A. If the test gives the maintenance message WRG: ZERO MACH-AOA PIN PROG:
Subtask 34-13-81-740-083-A - remove the ADIRU-1 (2 or 3) AMM 34-12-34-000-001.
- do a check of pin AA/5H and AA/5J on the rack connector.
- make sure that there is no ZERO MACH-AOA pin-programming on these pins.
- install a new ADIRU-1 [1FP1] ( ADIRU-2 [1FP2] or ADIRU-3 [1FP3] ) AMM 34-12-34-400-001.
- remove the
wiring ZERO MACH-AOA pin-programming of the ADIRU-1 (2 or 3) of pin AA/5H and pin AA/5J.
B. Do the test given in Para. 3.