W DOC AIRBUS | TSM A320F

Only the NAV ADR2 FAULT ECAM Warning is shown in the POST FLIGHT REPORT (PFR)


TASK 34-13-81-810-819-A
Only the NAV ADR2 FAULT ECAM Warning is shown in the POST FLIGHT REPORT (PFR)


1. Possible Causes
  • ADIRU-2 [1FP2]
  • CDU-ADIRS [2FP]
  • wiring between the ADIRS CDU (2FP) and the ADIRU2 (1FP2)
  • wiring
  • P/BSW-ADIRS/ADR2 (26FP2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-10-00-860-005
ADIRS Stop Procedure
AMM 34-12-12-000-001
Removal of the ADIRS CDU
AMM 34-12-12-400-001
Installation of the ADIRS CDU
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341302
3. Fault Confirmation
Subtask 34-13-81-700-052-A
A. Test
   (1) Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
Subtask 34-13-81-810-068-B ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the NAV ADR2 FAULT ECAM warning:
  • do a check of the status of the ADR2 pushbutton switch on the ADIRS CDU.
   (1) If the pilot pushed the ADR2 pushbutton switch during the flight:
  • no maintenance action is necessary.
   (2) If the pilot did not push the ADR2 pushbutton switch during the flight:
     (a) If there is a short to ground:
     (b) If there is no short to ground:
  • install a new ADIRS CDU
  • install the ADIRU2.
       1 If the fault continues:
  • replace the ADIRU2.
Subtask 34-13-81-810-068-C ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the NAV ADR2 FAULT ECAM warning:
  • Do a check of the status of the ADR2 pushbutton switch on the ADIRS MSU.
   (1) If the pilot pushed the ADR2 pushbutton switch during the flight:
  • No maintenance action is necessary.
   (2) If the pilot did not push the ADR2 pushbutton switch during the flight:
  • Remove the ADIRU-2 [1FP2] AMM 34-12-34-000-001
  • Do a check for a short to ground of the wiring between pin A/A1 of the ADIRS/ADR2 pushbutton switch (26FP2) and pin AA/4C of the ADIRU2 (1FP2) ASM 341302.
     (a) If there is a short to ground:
     (b) If there is no short to ground:
       1 If the fault continues:
5. Close-up
Subtask 34-13-81-860-052-A
A. Do the ADIRS stop procedure AMM 34-10-00-860-005.