W DOC AIRBUS | TSM A320F

Loss of the ADR3 BUS3 Interface with the EFCS1 Identified by the EFCS1


TASK 34-13-81-810-809-A
Loss of the ADR3 BUS3 Interface with the EFCS1 Identified by the EFCS1


1. Possible Causes
  • wiring between the terminal blocks 1851VT and 1831VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AWM 341126
3. Fault Confirmation
Subtask 34-13-81-740-066-A
A. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) (system 1) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-13-81-810-058-A
A. If the test gives the maintenance message ADR3 BUS 3:
  • do a check and repair the wiring between the terminal blocks 1851VT and 1831VT : between pins 43M, 44N and 3E, 5E AWM 341126.
Subtask 34-13-81-740-067-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:34 UTC