Loss of the ADR3 BUS3 Interface with the EFCS1 Identified by the EFCS1
TASK 34-13-81-810-809-A
Loss of the ADR3 BUS3 Interface with the EFCS1 Identified by the EFCS1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-066-A 4. Fault Isolation
Subtask 34-13-81-810-058-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:34 UTC
Loss of the ADR3 BUS3 Interface with the EFCS1 Identified by the EFCS1
1. Possible Causes
- wiring between the terminal blocks 1851VT and 1831VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AWM 341126 |
Subtask 34-13-81-740-066-A 4. Fault Isolation
Subtask 34-13-81-810-058-A
A. If the test gives the maintenance message ADR3 BUS 3:
Subtask 34-13-81-740-067-A - do a check and repair the wiring between the terminal blocks 1851VT and 1831VT : between pins 43M, 44N and 3E, 5E AWM 341126.
B. Do the test given in Para. 3.