Loss of the ADR3 BUS2 Interface with the EFCS1 Identified by the EFCS1


1. Possible Causes
  • wiring between the terminal blocks 1860VT and 1840VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AWM 341120
3. Fault Confirmation
Subtask 34-13-81-740-064-A
A. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) (system 1) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-13-81-810-057-A
A. If the test gives the maintenance message ADR3 BUS 2:
  • do a check and repair the wiring between the terminal blocks 1860VT and 1840VT : between pins 27T, 27C and 11A, 11D AWM 341120.
Subtask 34-13-81-740-065-A
B. Do the test given in Para. 3.