Loss of the ADR2 BUS3 Interface with the EFCS1 Identified by the EFCS1
TASK 34-13-81-810-806-A
Loss of the ADR2 BUS3 Interface with the EFCS1 Identified by the EFCS1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-060-A 4. Fault Isolation
Subtask 34-13-81-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:33 UTC
Loss of the ADR2 BUS3 Interface with the EFCS1 Identified by the EFCS1
1. Possible Causes
- wiring between the terminal blocks 1851VT and 1831VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AWM 341122 |
Subtask 34-13-81-740-060-A 4. Fault Isolation
Subtask 34-13-81-810-055-A
A. If the test gives the maintenance message ADR2 OR BUS 3 TO ELAC1:
Subtask 34-13-81-740-061-A - do a check and repair the wiring between the terminal blocks 1851VT and 1831VT : between pins 4M, 3M and 2R, 1H AWM 341122.
B. Do the test given in Para. 3.