Loss of the ADR2 BUS3 Interface with the EFCS1 Identified by the EFCS1


TASK 34-13-81-810-806-A
Loss of the ADR2 BUS3 Interface with the EFCS1 Identified by the EFCS1


1. Possible Causes
  • wiring between the terminal blocks 1851VT and 1831VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AWM 341122
3. Fault Confirmation
Subtask 34-13-81-740-060-A
A. Test
   (1) Do the BITE test of the EFCS (Ground scanning) (system 1) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-13-81-810-055-A
A. If the test gives the maintenance message ADR2 OR BUS 3 TO ELAC1:
  • do a check and repair the wiring between the terminal blocks 1851VT and 1831VT : between pins 4M, 3M and 2R, 1H AWM 341122.
Subtask 34-13-81-740-061-A
B. Do the test given in Para. 3.