W DOC AIRBUS | TSM A320F

Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS2


TASK 34-13-81-810-803-A
Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS2


1. Possible Causes
  • wiring between the terminal blocks 1860VT and 1840VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AWM 341118
3. Fault Confirmation
Subtask 34-13-81-740-054-A
A. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) (system 2) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-13-81-810-052-A
A. If the test gives the maintenance message ADR1 BUS 2:
  • do a check and repair the wiring between the terminal blocks 1860VT and 1840VT : between pins 28F, 27F and 76E, 75E AWM 341118.
Subtask 34-13-81-740-055-A
B. Do the test given in Para. 3.