1. Possible Causes
- wiring between the terminal blocks 1851VT and 1831VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AWM 341121 |
Subtask 34-13-81-740-052-A 4. Fault Isolation
Subtask 34-13-81-810-051-A
A. If the test gives the maintenance message ADR1 BUS 3:
Subtask 34-13-81-740-053-A - do a check and repair the wiring between the terminal blocks 1851VT and 1831VT : between pins 2M, 1M and 4F, 4B AWM 341121.