Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS1
TASK 34-13-81-810-801-A
Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-81-740-050-A 4. Fault Isolation
Subtask 34-13-81-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:33 UTC
Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS1
1. Possible Causes
- wiring between the terminal blocks 1860VT and 1840VT
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AWM 341118 |
Subtask 34-13-81-740-050-A 4. Fault Isolation
Subtask 34-13-81-810-050-A
A. If the test gives the maintenance message ADR1 BUS 2:
Subtask 34-13-81-740-051-A - do a check and repair the wiring between the terminal blocks 1860VT and 1840VT : between pins 28F, 27F and 76E, 75E AWM 341118.
B. Do the test given in Para. 3.