Failure of the ADR 1 or ADM SDI Pin-Programming


TASK 34-13-00-810-A04-A
Failure of the ADR 1 or ADM SDI Pin-Programming


1. Possible Causes
  • wiring of the defective programming-pins
  • ADM-L TOTAL PRESSURE [19FP1]
  • wiring of the defective pins
  • ADM-L STATIC PRESSURE [19FP5]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
ASM 341201
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341303
3. Fault Confirmation
Subtask 34-13-00-740-368-A ** ON A/C NOT FOR ALL
A. Test
Do the Interface test of the ADR (system 1) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-278-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU 1 or PROG PIN or ADM 19FP1 or ADM 19FP5:
  • do a check of SDI programming-pins AA/1A, 5A, 6A on the rack connector
  • compare the state of the pins with the SDI pin-programming given in the ASM ASM 341201.
   (1) If the pin-programming is incorrect:
  • repair the wiring of the defective programming-pins ASM 341201.
   (2) If the pin-programming is correct:
     (a) If the fault stops:
  • replace the ADIRU that you installed on side 2.
     (b) If the fault continues:
  • get access to the ADM-L TOTAL PRESSURE [19FP1] AMM 34-11-17-000-001
  • disconnect the electrical connector of the L total pressure ADM (19FP1)
  • make sure that there is continuity between pins A/J and K and that there is an open circuit between pins A/L, M, N and P.
       1 If the pin-programming is incorrect:
  • repair the wiring of the defective pins ASM 341303
  • connect the electrical connector of the L total pressure ADM (19FP1).
       2 If the pin-programming is correct:
  • get access to the ADM-L STATIC PRESSURE [19FP5] AMM 34-11-17-000-001
  • disconnect the electrical connector of the L static pressure ADM (19FP5)
  • make sure that there is continuity between pins A/J, K, M and P and that there is an open circuit between pins A/L and N.
         a If the pin-programming is incorrect:
  • repair the wiring of the defective pins ASM 341303
  • connect the electrical connector of the L static pressure ADM (19FP5).
         b If the pin-programming is correct:
Subtask 34-13-00-740-369-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.