Failure of the ADR1 AOA Average-Unique Pin-Programming
TASK 34-13-00-810-984-A
Failure of the ADR1 AOA Average-Unique Pin-Programming
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-329-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-233-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:32 UTC
Failure of the ADR1 AOA Average-Unique Pin-Programming
1. Possible Causes
- ADIRU-1 [1FP1]
- wiring of the AOA average-unique pin-programming of ADIRU1
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 341201 | |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-00-740-329-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-233-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message WRG:AOA AVERAGE-UNIQUE PIN PROG:
Subtask 34-13-00-740-330-A ** ON A/C NOT FOR ALL - Remove ADIRU1 AMM 34-12-34-000-001.
- Do a check of pin AA/5K on the rack connector.
- Compare the status of the pin with the AOA average-unique pin-programming given in ASM 341201.
- Install a new ADIRU-1 [1FP1] AMM 34-12-34-400-001.
- Repair the wiring of the AOA average-unique pin-programming of ADIRU1 : pin AA/5K.
- Install ADIRU1 AMM 34-12-34-400-001.
B. Do the test given in Para. 3.