Failure of the ADR2 Baro-Source Pin-Programming


TASK 34-13-00-810-979-A
Failure of the ADR2 Baro-Source Pin-Programming


1. Possible Causes
  • ADIRU-2 [1FP2]
  • aircraft wiring
  • wiring BARO PORT A SELECT pin programming of the ADIRU2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 341202
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-00-740-319-A ** ON A/C NOT FOR ALL
A. Test
Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-228-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message WRG: BARO SOURCE SELECT PIN PROG:
  • remove the ADIRU-2 [1FP2] AMM 34-12-34-000-001
  • do a check of the wiring and make sure that there is a ground signal at pin AA/7G and an open circuit at pin AA/7F on the rack connector.
   (1) If the pin programming is incorrect:
  • repair the aircraft wiring : defective pin
  • install the ADIRU2.
   (2) If the pin programming is correct:
  • do a check of pin AA/3C on the rack connector
  • compare the state of the pin with the BARO PORT A SELECT pin programming given in the ASM ASM 341202.
     (a) If the pin programming is correct:
     (b) If the pin programming is incorrect:
  • repair the wiring BARO PORT A SELECT pin programming of the ADIRU2 : pin AA/3C.
  • install the ADIRU2.
Subtask 34-13-00-740-320-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:32 UTC