Disagree between ADIRU2 and ADM2 SDI Codes


TASK 34-13-00-810-959-A
Disagree between ADIRU2 and ADM2 SDI Codes


1. Possible Causes
  • ADIRU-2 [1FP2]
  • SDI pin programming of the ADIRU2
  • ADM-R TOTAL PRESSURE [19FP2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
ASM 341202
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341303
3. Fault Confirmation
Subtask 34-13-00-740-283-A
A. Test
Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-210-A
A. If the test gives the maintenance message WRG: SDI PIN PROG/ ADM2 (19FP2)/ ADIRU2 (1FP2):
  • remove the ADIRU-2 [1FP2] AMM 34-12-34-000-001
  • do a check of the SDI pin programming pins AB/1A, 5A, 6A on the rack connector
  • compare the state of the pins with the SDI pin programming given in the ASM ASM 341202.
   (1) If the pin programming is incorrect:
   (2) If the pin programming is correct:
  • get access to the ADM (19FP2) AMM 34-11-17-000-001 (Para. 2.B.)
  • disconnect the electrical connector of the ADM (19FP2)
  • make sure that there is continuity between pins A/J, L and that there is an open circuit between pins A/K, M, N, P ASM 341303.
     (a) If the pin programming is incorrect:
  • repair the ADM-R TOTAL PRESSURE [19FP2]
  • connect the electrical connector of the ADM (19FP2)
  • install the ADIRU2.
     (b) If the pin programming is correct:
  • install a new ADIRU2
  • connect the electrical connector of the ADM (19FP2).
       1 If the fault continues:
Subtask 34-13-00-740-284-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:31 UTC