Incorrect ADM Data on Ground
TASK 34-13-00-810-952-A
Incorrect ADM Data on Ground
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-361-A
Subtask 34-13-00-810-260-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:30 UTC
Incorrect ADM Data on Ground
1. Possible Causes
- ADM-L TOTAL PRESSURE [19FP1]
- ADM-R TOTAL PRESSURE [19FP2]
- ADM-STBY TOTAL PRESSURE [19FP3]
- ADM-R STATIC PRESSURE [19FP4]
- ADM-L STATIC PRESSURE [19FP5]
- ADM-R STATIC PRESSURE [19FP6]
- ADM-L STATIC PRESSURE [19FP7]
- ADM-STBY STATIC PRESSURE [19FP8]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
Subtask 34-13-00-740-361-A
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationSubtask 34-13-00-810-260-A
A. If there is a repetitive RETARD aural warning message, do a check of the speed value on CAPT (ADR1) (or ADR3 after SWITCHING AIR DATA on CAPT position) and F/O (ADR2) (or ADR3 after SWITCHING AIR DATA on F/O position) PFDs:
(1) If a residual speed of 80 kts or more is shown on the speed scale on:
Subtask 34-13-00-810-261-A (1) If a residual speed of 80 kts or more is shown on the speed scale on:
- CAPT PFD (ADR1), replace the ADM-L TOTAL PRESSURE [19FP1] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- F/O PFD (ADR2), replace the ADM-R TOTAL PRESSURE [19FP2] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- CAPT PFD (ADR3), replace the ADM-STBY TOTAL PRESSURE [19FP3] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
B. If the fault continues, replace the ADM-R STATIC PRESSURE [19FP4] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
(1) If the fault continues, replace the ADM-L STATIC PRESSURE [19FP5] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
(a) If the fault continues, replace the ADM-R STATIC PRESSURE [19FP6] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
1 If the fault continues, replace the ADM-L STATIC PRESSURE [19FP7] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
a If the fault continues, replace the ADM-STBY STATIC PRESSURE [19FP8] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
(1) If the fault continues, replace the ADM-L STATIC PRESSURE [19FP5] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
(a) If the fault continues, replace the ADM-R STATIC PRESSURE [19FP6] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
1 If the fault continues, replace the ADM-L STATIC PRESSURE [19FP7] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
a If the fault continues, replace the ADM-STBY STATIC PRESSURE [19FP8] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.