Loss of the FCU Inputs on the ADIRU1
TASK 34-13-00-810-941-A
Loss of the FCU Inputs on the ADIRU1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-251-A 4. Fault Isolation
Subtask 34-13-00-810-194-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:30 UTC
Loss of the FCU Inputs on the ADIRU1
1. Possible Causes
- FCU [2CA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-00-740-251-A 4. Fault Isolation
Subtask 34-13-00-810-194-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message FCU (3CA):
Subtask 34-13-00-810-194-B ** ON A/C NOT FOR ALL - replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
A. If the BITE test gives the maintenance message FCU (3CA) EIS CP-L BUS or FCU (3CA) EIS CP-R BUS:
Subtask 34-13-00-740-252-A - replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
B. Do the test given in Para. 3.